Microwave Motion Sensor
-
Dimmable Motion Sensor
-
Presence Detectors Sensor
-
Dimmable LED Driver
-
PIR Motion Sensor
-
On Off Function Sensor
-
Sensor Driver
-
Daylight Sensor
-
DC Motion Sensor
-
UL Motion Sensor
-
DALI Motion Sensor
-
Wireless Motion Sensor
-
DALI2.0 Dimmable LED Driver
-
DALI Dimmable LED Driver
-
1-10V Dimmable LED Driver
-
Triac Dimmable LED Driver
-
LED Emergency Driver
-
IOT Driver
MC093S Microwave Motion Sensor 198-264VAC 50Hz Resistive Inductive
Place of Origin | China |
---|---|
Brand Name | Merrytek |
Certification | CE/RED |
Model Number | MC093S |
Minimum Order Quantity | 100pcs |
Price | Negotiation |
Packaging Details | Bubble bag + partition + outer box (K=A) |
Delivery Time | within 5 working days for sample and small order; within 3-4 weeks for bulk order |
Payment Terms | T/T, Western Union |
Supply Ability | 10,000pcs per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOperating Voltage Range | 198-264V AC 50Hz | Stand-by Power | ≤0.5W |
---|---|---|---|
Operating Frequency | 5.8GHz ±75 MHz. | Hold Time | 5S/30S/60S/3Min/5Min/10Min/20Min/30Min(adjust By 3 DIP Switches) |
Detection Area | 100%/75%/50%/25% (adjust By 2 DIP Switches) | Detecting Radius | 4-6M (mounted At 3M Height) |
Highlight | 800W Microwave Motion Sensor,264VAC Floodlight Motion Sensor,Resistive Inductive Microwave Motion Sensor |
Microwave Motion Sensor Human Sensor for Accurately Detecting with Patented Low Impedance Antenna MC093S
1. Features
1) Built-in daylight sensor and human sensor, which can automatically switch on/off based on ambient light and human motion.
2) Using the latest human detection technology to detect small movements such as shaking head, turning around and etc. suitable for office field.
3) Patented low impedance antenna design, anti air conditioning, ventilator and other interference;
4) Support for different kind of application way.
5) Override sensor function by switch on and off power 3 times
6) DIP Switch design, users can configure the parameters according to their needs.
2. Parameters
Input | Operating Voltage | 198-264V AC 50Hz |
Rated Voltage | 220-240V AC 50Hz | |
Stand-by Power | ≤0.5W | |
Surge Test | Between L and N: 1KV | |
Output | Working Mode | ON/OFF |
Type of Load | Resistive or Inductive | |
Load Capacity | 800W (Resistive) or 400W (Inductive) | |
Max. Surge Capacity |
30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start) 60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start) |
|
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz. |
Transmitting power | 0.3mW Max. | |
Hold time | 5S/30S/60S/3Min/5Min/10Min/20Min/30Min(adjust by 3 DIP Switches) | |
Detection Area | 100%/75%/50%/25% (adjust by 2 DIP Switches) | |
Daylight Sensor | 25lux/50lux/100lux/300lux/Disable(adjust by 4 DIP Switches)(Diffusion state) | |
Detecting Radius | 4-6M (mounted at 3M height) (see Note 2) | |
Mounting Height | Supportable installation height: 2.5-6m maximum induction distance installation height: 2.5m | |
Detecting Angle | Ceiling mount 150° | |
Operating Environment |
Operating Temperature | -25℃…+60℃ |
Storage Temperature | -40℃…+80℃; Humidity: 10%-95% (non-condensing) | |
Certificate Standards | Safety standards | EN61058-1 |
EMC standards | EN300440 EN301489-1 EN55015 EN61547 EN61000-3-2 EN61000-3-3 EN62479 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | CE RED | |
Others | Input/output terminal | screw terminal block Wire diameter:0.75-1.5mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in installation | |
Dimension | 65*65*28mm | |
Package | Bubble bag + partition + outer box (K=A) | |
Net Weight | 59±2g | |
Lifetime | 50,000h @ Ta Full load | |
Note 1. “N/A”means not available. 2. the induced distance is related to the moving speed and volume of moving objects. This data is obtained from the personnel test of 170 cm high moving speed of 0.3 m/s. |
3.Function
1) On/OFF Function
4.Dimension (mm)
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
5.Installation guide:
For panel light (cut size of 40*40mm) | For ceiling lamp |
|
Top mounting(cut size of 40*40mm) |
Base mounting
|
6.Function diagram
7.Wiring
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
8. Radiation pattern
1)Ceiling mounting
9. DIP switch
1)Detection Area
1 | 2 | ||
Ⅰ | ON | ON | 100% |
Ⅱ | - | ON | 75% |
Ⅲ | ON | - | 50% |
Ⅳ | - | - | 25% |
2) Hold Time
3 | 4 | 5 | ||
Ⅰ | ON | ON | ON | 5S |
Ⅱ | ON | - | ON | 30s |
Ⅲ | ON | ON | - | 1min |
Ⅳ | ON | - | - | 3min |
Ⅴ | - | ON | ON | 5min |
Ⅵ | - | - | ON | 10min |
Ⅶ | - | ON | - | 20min |
Ⅷ | - | - | - | 30min |
3) Daylight Sensor
6 | 7 | 8 | ||
Ⅰ | ON | ON | ON | 25Lux |
Ⅱ | ON | ON | - | 50Lux |
Ⅲ | ON | - | - | 100Lux |
Ⅳ | - | ON | ON | 300lux |
Ⅴ | - | - | - | Disable |
4) Minor motion indicator
9 | ||
Ⅰ | ON | Turn on |
Ⅱ | - | Turn off |
10. Cancel sensor function
Sensor function can be canceled by switch on /off power 3 time in 2s, Turn on the power again, sensor function come back .
11. Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 30sec, it turns off the light. During the initialization, the sensor is not able to detect movement.
12. Default Settings
Detection area: 100%, Hold time: 3min, Daylight sensor: Disable ,Minor motion indicator:Turn off
13. Notes for Application
1), The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.
2), The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection.
Ambient lux level could be different in different environment, weather, climate, time-of-day and season.
3),The parameters of the sensor may need to be reconfigured in different installation environments.
4),This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.