Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods

Place of Origin Shenzhen, China
Brand Name Merrytek
Certification UL FCC
Model Number MC090S U2
Minimum Order Quantity 100PCS
Price Negotiation
Packaging Details Bubble bag + Partition + Carton
Delivery Time 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Payment Terms T/T
Supply Ability 10000 pcs/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Operaing Voltage 100-305VAC Rated Voltage 120-277VAC
Working Mode ON/OFF Opearing Fequency 5.8GHz
Certificate UL FCC IP Rating IP20
Leave a Message
Product Description

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods

 

1.Feature

  • Special motion sensor for sterilizing lamp: the light turn off when detect people come; the light turn on when people leave.
  • Free ISM band 5.8ghz microwave band, active detection, stable and reliable.
  • Ultra-small installation size, multiple installation methods (surface and bottom screw installation)
  • Batch products to ensure compliance with FCC certification requirements, the lamp with sensor certification is guaranteed.

 

2.Parameters

 

Input Operating Voltage Range 100-305VAC 50/60Hz
DC Input Voltage N/A
Rated Voltage 120-277VAC 50/60Hz
No-load Power ≤1.2W
Stand-by Power ≤0.5W
Surge Test Between L and N: 1KV
Output Working Mode ON/OFF
Type of Load Resistive or Capacitive
Load Capacity 800W (Resistive) or 400W (Capacitive)
Current of Load N/A
Load surge current 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load)
Interface 1-10V dimmer N/A
Synchronization control interface N/A
High and Low Level Interface N/A
PWM control interface N/A
Interface terminal wiring mode N/A
Sensor Operating Frequency 5.8 GHz ±74.9 MHz.ISM wave band
Transmitting power 0.5mW Max.
Delay time 5S/30S/60S/3min/5min/10min/20min/30min
Hold time 15min/30min/60min/120min//+∞
DIM down N/A
Cut off N/A
Detection Area 100% / 75% / 50% / 25%
Hold time 2(sterilizing time) 15min/30Min/60Min/120Min/+∞
Daylight on/off N/A
Detecting Radius 4-7m(mounting height 3m )
Mounting Height 2.5-6 m(Suction Top Installation)
Detecting Angle Ceiling mount 150°
Wireless module Operating Frequency N/A
Transmitting power N/A
transmission distance N/A
modulation mode N/A
Coding group number N/A

Operating

Environment

Operating Temperature -20℃…+60℃ Humidity: 85% (non-condensing)
Storage Temperature -40℃…+80℃
Certificate Standards Safety (LVD)standards EN61058-1,EN61058-1-2
EMC standards EN55015,EN61547,EN61000-3-2,EN61000-3-3
Environmental Requirement RoHS
Certificate UL FCC
Others Input/output terminal specifications 0.5-0.75mm2
IP Rating IP20
Protection Class Class II
Installation Built-in installation
Dimension 62*36*25mm
Package Bubble bag + partition + outer box (K=A)
Net Weight 36g
Lifetime 5 years warranty@Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s.

 
3.Function
on/off function
Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 0
 

4. Dimension (mm)

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 1

 

5. Wiring

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 2

 

6. Structure

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 3

 

7. Radiation Pattern

Ceiling mounting

Ceiling mounted height: 3m

Sensitivity: 100%/75%/50%/25%

Ceiling mounted height: 6m(*)

Sensitivity:100%/75%/50%

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 4

Normal moving (Speed:1m/s)

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 5

Normal moving (Speed:1m/s)

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 6

Slow moving (Speed 0.3m/s)

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 7

Slow moving (Speed: 0.3m/s)

* 50%,75%,100% detection sensitivity is workable when installed at 6 m mounting height. Only 25% sensitivity is not able to detect motion signal.

 

Wall mounting

Wall mounted height: 2m

Sensitivity: 100%/75%/50%/25%

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 8

Normal moving (Speed:1m/s)

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 9

Slow moving (Speed 0.3m/s)

 

8. Function Dialing Settings

Detection Area

  1 2  

ON ON 100%

ON

-

75%

-

ON 50%

-

-

25%

 

Delay Time

  3 4 5  
ON ON ON 5S
ON ON - 30S
ON - ON 1min
IV ON - - 3min
V - ON ON 5min
VI - ON - 10min
VII - - ON 20min
VIII - - - +∞

 

Hold Time

  6 7 8  
ON ON ON 15min
ON ON - 30min
- ON - 1H
V ON - - 2H
IV - - - +∞
 
9. Initialization

Attachment:

1>. Self-test: there is no output of self-test on power (12S). After self-test 2 seconds detection. The sterilization light was turn on when no one trigger the sensor ,No output when the detect human body was moving, and the sterilization light was on after the pre-set delay time when the human being left.

2>. Delay time: after the human being left, the pre set delay time enter into the hold time (the sterilizing time).

3>.Hold time: The time of the sterilization light on, the hold time has the interrupt function, the hold time (the sterilization light is on), when the human being came ,the light will be turn off, after the human being leaves,the sensor get into the delay time, after run the delay time, the sterilization light will be turn on. The hold time will not start the timer from the beginning, it will continue to account the time base on previous lighting time, until the pre set hold time finished ,then the light off, need to power again after the restart.

 

10. Factory settings

Detection Area: 100%, Delay Time: 5S, Hold Time2: +∞

 

11. Use Caution

1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.

2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.

3. It has to be at least 15mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.

Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods 10