Microwave Motion Sensor
-
Dimmable Motion Sensor
-
Smart Home Sensor
-
Dimmable LED Driver
-
PIR Motion Sensor
-
On Off Function Sensor
-
Sensor Driver
-
Daylight Sensor
-
DC Motion Sensor
-
UL Motion Sensor
-
DALI Motion Sensor
-
Wireless Motion Sensor
-
DALI2.0 Dimmable LED Driver
-
DALI Dimmable LED Driver
-
1-10V Dimmable LED Driver
-
Triac Dimmable LED Driver
-
LED Emergency Driver
-
IOT Driver
Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods
Place of Origin | Shenzhen, China |
---|---|
Brand Name | Merrytek |
Certification | UL FCC |
Model Number | MC090S U2 |
Minimum Order Quantity | 100PCS |
Price | Negotiation |
Packaging Details | Bubble bag + Partition + Carton |
Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit. |
Payment Terms | T/T |
Supply Ability | 10000 pcs/month |
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOperaing Voltage | 100-305VAC | Rated Voltage | 120-277VAC |
---|---|---|---|
Working Mode | ON/OFF | Opearing Fequency | 5.8GHz |
Certificate | UL FCC | IP Rating | IP20 |
Ultra-Small Size UL Approved MC090S U2 Microwave Motion Sensor Multiple Installation Methods
1.Feature
- Special motion sensor for sterilizing lamp: the light turn off when detect people come; the light turn on when people leave.
- Free ISM band 5.8ghz microwave band, active detection, stable and reliable.
- Ultra-small installation size, multiple installation methods (surface and bottom screw installation)
- Batch products to ensure compliance with FCC certification requirements, the lamp with sensor certification is guaranteed.
2.Parameters
Input | Operating Voltage Range | 100-305VAC 50/60Hz |
DC Input Voltage | N/A | |
Rated Voltage | 120-277VAC 50/60Hz | |
No-load Power | ≤1.2W | |
Stand-by Power | ≤0.5W | |
Surge Test | Between L and N: 1KV | |
Output | Working Mode | ON/OFF |
Type of Load | Resistive or Capacitive | |
Load Capacity | 800W (Resistive) or 400W (Capacitive) | |
Current of Load | N/A | |
Load surge current | 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load) | |
Interface | 1-10V dimmer | N/A |
Synchronization control interface | N/A | |
High and Low Level Interface | N/A | |
PWM control interface | N/A | |
Interface terminal wiring mode | N/A | |
Sensor | Operating Frequency | 5.8 GHz ±74.9 MHz.ISM wave band |
Transmitting power | 0.5mW Max. | |
Delay time | 5S/30S/60S/3min/5min/10min/20min/30min | |
Hold time | 15min/30min/60min/120min//+∞ | |
DIM down | N/A | |
Cut off | N/A | |
Detection Area | 100% / 75% / 50% / 25% | |
Hold time 2(sterilizing time) | 15min/30Min/60Min/120Min/+∞ | |
Daylight on/off | N/A | |
Detecting Radius | 4-7m(mounting height 3m ) | |
Mounting Height | 2.5-6 m(Suction Top Installation) | |
Detecting Angle | Ceiling mount 150° | |
Wireless module | Operating Frequency | N/A |
Transmitting power | N/A | |
transmission distance | N/A | |
modulation mode | N/A | |
Coding group number | N/A | |
Operating Environment |
Operating Temperature | -20℃…+60℃ Humidity: 85% (non-condensing) |
Storage Temperature | -40℃…+80℃ | |
Certificate Standards | Safety (LVD)standards | EN61058-1,EN61058-1-2 |
EMC standards | EN55015,EN61547,EN61000-3-2,EN61000-3-3 | |
Environmental Requirement | RoHS | |
Certificate | UL FCC | |
Others | Input/output terminal specifications | 0.5-0.75mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in installation | |
Dimension | 62*36*25mm | |
Package | Bubble bag + partition + outer box (K=A) | |
Net Weight | 36g | |
Lifetime | 5 years warranty@Ta 230V full load | |
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. |
4. Dimension (mm)
5. Wiring
6. Structure
7. Radiation Pattern
Ceiling mounting
Ceiling mounted height: 3m Sensitivity: 100%/75%/50%/25% |
Ceiling mounted height: 6m(*) Sensitivity:100%/75%/50% |
Normal moving (Speed:1m/s) |
Normal moving (Speed:1m/s) |
Slow moving (Speed 0.3m/s) |
Slow moving (Speed: 0.3m/s) |
* 50%,75%,100% detection sensitivity is workable when installed at 6 m mounting height. Only 25% sensitivity is not able to detect motion signal. |
Wall mounting
Wall mounted height: 2m Sensitivity: 100%/75%/50%/25% |
|
Normal moving (Speed:1m/s) |
Slow moving (Speed 0.3m/s) |
8. Function Dialing Settings
Detection Area
1 | 2 | ||
Ⅰ |
ON | ON | 100% |
Ⅱ |
ON |
- |
75% |
Ⅲ |
- |
ON | 50% |
Ⅳ |
- |
- |
25% |
Delay Time
3 | 4 | 5 | ||
Ⅰ | ON | ON | ON | 5S |
Ⅱ | ON | ON | - | 30S |
Ⅲ | ON | - | ON | 1min |
IV | ON | - | - | 3min |
V | - | ON | ON | 5min |
VI | - | ON | - | 10min |
VII | - | - | ON | 20min |
VIII | - | - | - | +∞ |
Hold Time
6 | 7 | 8 | ||
Ⅰ | ON | ON | ON | 15min |
Ⅱ | ON | ON | - | 30min |
Ⅲ | - | ON | - | 1H |
V | ON | - | - | 2H |
IV | - | - | - | +∞ |
Attachment:
1>. Self-test: there is no output of self-test on power (12S). After self-test 2 seconds detection. The sterilization light was turn on when no one trigger the sensor ,No output when the detect human body was moving, and the sterilization light was on after the pre-set delay time when the human being left.
2>. Delay time: after the human being left, the pre set delay time enter into the hold time (the sterilizing time).
3>.Hold time: The time of the sterilization light on, the hold time has the interrupt function, the hold time (the sterilization light is on), when the human being came ,the light will be turn off, after the human being leaves,the sensor get into the delay time, after run the delay time, the sterilization light will be turn on. The hold time will not start the timer from the beginning, it will continue to account the time base on previous lighting time, until the pre set hold time finished ,then the light off, need to power again after the restart.
10. Factory settings
Detection Area: 100%, Delay Time: 5S, Hold Time2: +∞
11. Use Caution
1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.
2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.
3. It has to be at least 15mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.