Product Details
Operating Voltage 220-240VAC 50/60Hz Stand-by Power ≤0.5W
Daylight Sensor 2Lux/10Lux/25Lux/50Lux/Disable Mounting Height 2.5-6 M
Operating Temperature -20℃~+60℃ Certificate Requirement CE, TUV & RED
Installation Built-in Installation IP Rating IP20
Dimension 62*36*25mm Lifetime 5 Years Warranty @Ta 230V Full Load
Highlight

Press In Terminal Motion Sensor

,

264VAC Microwave Motion Sensor

,

Automatic Switching Microwave Motion Sensor

Leave a Message
Product Description

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal

 

Product Feature

  • Microwave motion detection version.
  • Eight DIP switch setting, distance, time, daylight sensor, multi-speed adjustable.
  • Ultra-small mounting size, multiple mounting options, support for top and bottom mounting options.
  • Super cost-effective, support a variety of lamps, tri-proof lamps, ceiling lamps.
  • The infrared sensor is used to filter out the light sensor, and the light sensitivity value is more accurate, and is not affected by cloudy and sunny days.
  • Low impedance 5.8G antenna for superior immunity to interference.
  • Batch over RED, TUV certification.
  • 5 years warranty

 

Parameters

 

Input Rated Voltage 220-240VAC 50/60Hz
No-load Power ≤1.0W
Stand-by Power ≤0.5W
Surge Test Between L and N: 1KV
Output Working Mode ON/OFF
Type of Load Resistive or Capacitive
Load Capacity 800W (Resistive) or 400W (Capacitive)
Load surge current 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load)
Sensor Operating Frequency 5.8 GHz ±74.9 MHz.ISM wave band
Transmitting power 0.5mW Max.
Hold time 5S/30S/60S/3min/5min/10min/20min/30min
Detection Area 100% / 75% / 50% / 25%
Daylight Sensor 2Lux/10Lux/25Lux/50Lux/Disable
Detecting Radius (Detection Area: 100%) Ceiling Mounting at 3m: 0.3m/S ≥4m, 1m/S ≥2.5m
Wall Mounting at 2m: 0.3m/S ≥8m, 1m/S ≥4m
Mounting Height 2.5-6 m(Suction Top Installation)
Detecting Angle 90°@Xz filed / 95°@Yz filed

Operating

Environment

Operating Temperature -20℃…+60℃ Humidity: 85% (non-condensing)
Storage Temperature -40℃…+80℃

Maximum

shell temperature(Tc)

80℃
Certificate Standards Safety standards EN61058-1
EMC standards EN300440, EN301489-1, EN55015, EN61547, EN61000-3-2, EN61000-3-3, EN62479
Environmental Requirement RoHS
Certificate CE, TUV & RED
Others Input/output terminal specifications 0.5-0.75mm2
IP Rating IP20
Protection Class Class II
Installation Built-in installation
Dimension 62*36*25mm
Package Bubble bag + partition + outer box (K=A)
Net Weight 36g
Lifetime 5 years warranty @Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s.

 

 

【Function Description】

On/OFF Function
Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 0
 
Dimension(mm)
Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 1
 
Wiring
Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 2

*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.

 

Structure

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 3

 

Radiation Pattern

Ceiling mounting

Ceiling mounted height: 3m

Sensitivity: 100%/75%/50%/25%

Ceiling mounted height: 6m(*)

Sensitivity:100%/75%/50%

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 4

Normal moving (Speed:1m/s)

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 5

Normal moving (Speed:1m/s)

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 6

Slow moving (Speed 0.3m/s)

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 7

Slow moving (Speed: 0.3m/s)

 

*50%,75%,100% detection sensitivity is workable when installed at 6m mounting height. Only 25% sensitivity is not able to detect motion signal.

 

Wall mounting:

Wall mounted height: 2m

Sensitivity: 100%/75%/50%/25%

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 8

Normal moving (Speed:1m/s)

Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal 9

Slow moving (Speed 0.3m/s)

 
 
Function Dialing Settings

Detection Area

  1 2  
ON ON 100%
ON - 75%
- ON 50%
- - 25%

 

Hold Time

  3 4 5  
ON ON ON 5S
ON ON - 30S
ON - ON 1min
ON - - 3min
- ON ON 5min
- ON - 10min
- - ON 20min
- - - 30min

 

Daylight Sensor

  6 7 8  
ON ON ON 2Lux
ON ON - 10Lux
- ON - 25Lux
ON - - 50Lux
- - - Disable

 

*When set to Disable gear, the sensor will turn on the light as long as the motion of the object is detected, regardless of whether the illumination is adequate or not.

 
Override Function
 

Power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.

 

Initialization

 

After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.

 

Factory settings

 

Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable

 

Use Caution

 

  • Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.
  • The microwave cannot pass through the metal, make sure there are no metal above the sensor.
  • It has to be at least 3.5mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.