Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal
Place of Origin | China |
---|---|
Brand Name | Merrytek |
Certification | CE, TUV & RED |
Model Number | MC090S E |
Minimum Order Quantity | 100pcs |
Price | Negotiation |
Packaging Details | Packed in bubble bag firstly, and then reinforced with carton for outer packing |
Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit. |
Payment Terms | T/T |
Supply Ability | 10,000pcs per month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOperating Voltage | 220-240VAC 50/60Hz | Stand-by Power | ≤0.5W |
---|---|---|---|
Daylight Sensor | 2Lux/10Lux/25Lux/50Lux/Disable | Mounting Height | 2.5-6 M |
Operating Temperature | -20℃~+60℃ | Certificate Requirement | CE, TUV & RED |
Installation | Built-in Installation | IP Rating | IP20 |
Dimension | 62*36*25mm | Lifetime | 5 Years Warranty @Ta 230V Full Load |
Highlight | Press In Terminal Motion Sensor,264VAC Microwave Motion Sensor,Automatic Switching Microwave Motion Sensor |
Automatic Switching Microwave Motion Sensor With 4 Pole Press In Terminal
【Product Feature】
- Microwave motion detection version.
- Eight DIP switch setting, distance, time, daylight sensor, multi-speed adjustable.
- Ultra-small mounting size, multiple mounting options, support for top and bottom mounting options.
- Super cost-effective, support a variety of lamps, tri-proof lamps, ceiling lamps.
- The infrared sensor is used to filter out the light sensor, and the light sensitivity value is more accurate, and is not affected by cloudy and sunny days.
- Low impedance 5.8G antenna for superior immunity to interference.
- Batch over RED, TUV certification.
- 5 years warranty
【Parameters】
Input | Rated Voltage | 220-240VAC 50/60Hz |
No-load Power | ≤1.0W | |
Stand-by Power | ≤0.5W | |
Surge Test | Between L and N: 1KV | |
Output | Working Mode | ON/OFF |
Type of Load | Resistive or Capacitive | |
Load Capacity | 800W (Resistive) or 400W (Capacitive) | |
Load surge current | 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load) | |
Sensor | Operating Frequency | 5.8 GHz ±74.9 MHz.ISM wave band |
Transmitting power | 0.5mW Max. | |
Hold time | 5S/30S/60S/3min/5min/10min/20min/30min | |
Detection Area | 100% / 75% / 50% / 25% | |
Daylight Sensor | 2Lux/10Lux/25Lux/50Lux/Disable | |
Detecting Radius (Detection Area: 100%) | Ceiling Mounting at 3m: 0.3m/S ≥4m, 1m/S ≥2.5m | |
Wall Mounting at 2m: 0.3m/S ≥8m, 1m/S ≥4m | ||
Mounting Height | 2.5-6 m(Suction Top Installation) | |
Detecting Angle | 90°@Xz filed / 95°@Yz filed | |
Operating Environment |
Operating Temperature | -20℃…+60℃ Humidity: 85% (non-condensing) |
Storage Temperature | -40℃…+80℃ | |
Maximum shell temperature(Tc) |
80℃ | |
Certificate Standards | Safety standards | EN61058-1 |
EMC standards | EN300440, EN301489-1, EN55015, EN61547, EN61000-3-2, EN61000-3-3, EN62479 | |
Environmental Requirement | RoHS | |
Certificate | CE, TUV & RED | |
Others | Input/output terminal specifications | 0.5-0.75mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in installation | |
Dimension | 62*36*25mm | |
Package | Bubble bag + partition + outer box (K=A) | |
Net Weight | 36g | |
Lifetime | 5 years warranty @Ta 230V full load | |
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. |
【Function Description】



*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
【Structure】
【Radiation Pattern】
Ceiling mounting
Ceiling mounted height: 3m Sensitivity: 100%/75%/50%/25% |
Ceiling mounted height: 6m(*) Sensitivity:100%/75%/50% |
Normal moving (Speed:1m/s) |
Normal moving (Speed:1m/s) |
Slow moving (Speed 0.3m/s) |
Slow moving (Speed: 0.3m/s) |
*50%,75%,100% detection sensitivity is workable when installed at 6m mounting height. Only 25% sensitivity is not able to detect motion signal.
Wall mounting:
Wall mounted height: 2m Sensitivity: 100%/75%/50%/25% |
|
Normal moving (Speed:1m/s) |
Slow moving (Speed 0.3m/s) |
Detection Area
1 | 2 | ||
Ⅰ | ON | ON | 100% |
Ⅱ | ON | - | 75% |
Ⅲ | - | ON | 50% |
Ⅳ | - | - | 25% |
Hold Time
3 | 4 | 5 | ||
Ⅰ | ON | ON | ON | 5S |
Ⅱ | ON | ON | - | 30S |
Ⅲ | ON | - | ON | 1min |
Ⅳ | ON | - | - | 3min |
Ⅴ | - | ON | ON | 5min |
Ⅵ | - | ON | - | 10min |
Ⅶ | - | - | ON | 20min |
Ⅷ | - | - | - | 30min |
Daylight Sensor
6 | 7 | 8 | ||
Ⅰ | ON | ON | ON | 2Lux |
Ⅱ | ON | ON | - | 10Lux |
Ⅲ | - | ON | - | 25Lux |
Ⅳ | ON | - | - | 50Lux |
Ⅴ | - | - | - | Disable |
*When set to Disable gear, the sensor will turn on the light as long as the motion of the object is detected, regardless of whether the illumination is adequate or not.
Power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.
【Initialization】
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.
【Factory settings】
Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable
【Use Caution】
- Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.
- The microwave cannot pass through the metal, make sure there are no metal above the sensor.
- It has to be at least 3.5mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.