Microwave Motion Sensor
-
Dimmable Motion Sensor
-
Presence Detectors Sensor
-
Dimmable LED Driver
-
PIR Motion Sensor
-
On Off Function Sensor
-
Sensor Driver
-
Daylight Sensor
-
DC Motion Sensor
-
UL Motion Sensor
-
DALI Motion Sensor
-
Wireless Motion Sensor
-
DALI2.0 Dimmable LED Driver
-
DALI Dimmable LED Driver
-
1-10V Dimmable LED Driver
-
Triac Dimmable LED Driver
-
LED Emergency Driver
-
IOT Driver
ON/OFF Motion Sensor For Tri-proof Light, Bottom Dip Switch And Remote Setting Available
| Place of Origin | Shenzhen, China |
|---|---|
| Brand Name | Merrytek |
| Certification | CE, RED |
| Model Number | MC098S F1 |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Bubble bag+Clapboard + Carton(K=A) |
| Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 4-5 weeks after receiving deposit. |
| Payment Terms | T/T |
| Supply Ability | 10000 pcs/month |
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Rated Voltage | 220-240V AC, 50Hz/60Hz | Stand-by Power | ≤0.5W |
|---|---|---|---|
| Load Capacity | 400W (Inductive) ; 800W (Resistive) | Working Mode | ON/OFF Function |
| Mounting Height | 3m (Max 6m) | Lifetime | 5 Years Warranty @Ta 230V Full Load |
| Highlight | ON/OFF motion sensor for tri-proof light,bottom dip switch motion sensor,remote setting motion sensor |
||
- Low Impedance sensor antenna patent helps anti-interference from wireless signals like 5G, Wi-Fi, Bluetooth
- Patented dipole antenna design provides reliable detection, avoiding false triggers when sensor is built into metal LED plates
- Bulk orders compliant with RED approval
- Adjustable detecting sensitivity via DIP switches for various installation sites
- Ultra-slim design compatible with Tri-proof LED lamps & ceiling lamps
- Supports maximum mounting height of 6m
- Switching power supply maintains PF value of the entire lamp, compliant with latest ERP standards
- Supports both dialing code and remote control (MH03) for parameter settings
- 5 years warranty
| Input | |
|---|---|
| Operating Voltage Range | 120-277V AC 50Hz/60Hz |
| Rated Voltage | 220-240V AC, 50Hz/60Hz |
| Stand-by Power | ≤0.5W |
| Surge Test | L--N: 1kV |
| Output | |
| Working Mode | ON/OFF function |
| Type of Load | Inductive or Resistive |
| Load Capacity | 400W (Inductive); 800W (Resistive) |
| Max. Surge Capacity | 30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start) |
| Sensor Parameters | |
| Operating Frequency | 5.8 GHz ±75 MHz, ISM Band |
| Transmitting power | 1mW Max. |
| Hold time | 5S/30S/90S/5Min 10S/90S/3Min/10min (by remote MH03) |
| Detection Sensitivity | 100%/75%/50%/25% 100%/50% (by remote MH03) |
| Daylight Sensor | 25lux/Disable 5lux/15lux/50lux/Disable (by remote MH03) |
| Detecting Radius | Ceiling mounting 3m high: 1m/S ≥2.5m (for built in lamp installation) Wall mounting 2m high: 1M /S ≥4m (for built in lamp installation) |
| Mounting Height | 3m (Max 6m) |
| Detecting Angle | 150° (Wall mounted) |
| Switch 1 | Switch 2 | Sensitivity |
|---|---|---|
| ON | ON | 100% |
| - | ON | 75% |
| ON | - | 50% |
| - | - | 25% |
| Switch 3 | Switch 4 | Hold Time |
|---|---|---|
| ON | ON | 5S |
| - | ON | 30S |
| ON | - | 90S |
| - | - | 5min |
| Switch 5 | Light Level |
|---|---|
| ON | 25Lux |
| - | Disable |
After power on, the sensor automatically turns on light at 100% brightness. After 10 seconds, it turns off the light. During initialization, the sensor is not able to detect movement.
Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable
- The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, or changing DIP switch settings.
- Microwave cannot penetrate metal. Avoid installing in closed or semi-closed metal lamps. Ensure no metal or glass cover above the product. If antenna must pass through metal plate, ensure sensor top is pressed against the metal plate.
- Installation distance between microwave sensors should be greater than 1.5m. Keep away from switches, routers, and other wireless devices to avoid radio interference. Antenna surface must be away from input AC and output DC to avoid signal interference.
- Avoid installing near long-term vibration equipment or moving objects. Vibration signals may trigger false detection. Installation should be away from large metal equipment, ventilation pipes, air conditioning outlets, exhaust vents, and smoke exhaust machines. Pets passing through detection area may trigger the sensor.
- This product is for indoor use only. Semi-outdoor or outdoor installation may cause wind/rain to trigger false detection. When installed in metal lamps, reflective surfaces, or narrow environments, microwave reflection may cause false triggers. Reduce sensitivity or contact manufacturer for support.
- Sensor is optimized for ceiling mounting. Wall installation increases detection distance and may cause microwave penetration through walls or failure to turn off lights. Try lowering sensitivity; if 25% doesn't work, avoid wall mounting or contact manufacturer.
- Product specifications and parameters may be optimized without prior notice.
- Sensing distance depends on object movement speed, object size, installation height, installation angle, environment, and reflective materials.
- Detection distances in specifications are typical values obtained with 165cm testers in indoor open environments.
- If antenna must pass through metal plate, hole should be no less than 20×8mm, and sensor top must be close to metal plate. Antenna should be exposed at opening with sensor shell top close to metal plate.