Product Details
Rated Voltage 220-240V AC, 50Hz/60Hz Stand-by Power ≤0.5W
Working Mode ON/OFF Function Load Capacity 400W(Inductive) ; 800W(Resistive)
Mounting Height 2.5-6m Lifetime 5 Years Warranty @Ta 230V Full Load
Highlight

ultra slim tri-proof light motion sensor

,

on off motion sensor with dip switch

,

ERP compliant motion sensor light

Leave a Message
Product Description
Ultra Slim Tri-proof Light ON/OFF Motion Sensor
Product Features
  • Low Impedance sensor antenna patent helps anti-interference from wireless signals like 5G, Wi-Fi, Bluetooth
  • Patented dipole antenna design provides reliable detection, avoiding false triggers when sensor is built into metal LED plates
  • Complies with RED approval standards
  • Non-isolated switching power supply maintains PF value compliance with latest ERP standards
  • Adjustable detection sensitivity via DIP switches for various installation sites
  • Ultra-slim design specifically for Tri-proof LED lights
  • Supports maximum mounting height of 6 meters
  • 5-year warranty
Technical Parameters
Input Specifications
Operating Voltage Range198-264V AC, 50Hz/60Hz
Rated Voltage220-240V AC, 50Hz/60Hz
Stand-by Power≤0.5W
Surge TestL-N: 1kV
Output Specifications
Working ModeON/OFF function
Type of LoadInductive or Resistive
Load Capacity400W (Inductive); 800W (Resistive)
Max. Surge Capacity30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start); 60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
Sensor Parameters
Operating Frequency5.8 GHz ±75 MHz, ISM Band
Transmitting Power0.5mW Max.
Hold Time5s/30s/90s/5min/20min/30min
Detection Sensitivity100%/75%/50%/25%
Daylight Sensor2Lux/10Lux/30Lux/50Lux/Disable
Detecting Radius4-6m (mounting height 3m)
Mounting Height2.5-6m supported, 4m for maximum detecting radius
Detecting Angle150° (Wall mounted), 360° (Ceiling mounted)
Operating Environment
Operating Temperature-25℃ to +60℃
Storage Temperature-40℃ to +80℃ (Humidity: 10%-95% Non-condensing)
Certificate Standards
Safety StandardsEN61058-1
EMC StandardsEN300440; EN301489-1; EN55015; EN61547; EN61000-3-2; EN61000-3-3; EN62479
Environmental RequirementCompliant to RoHS
CertificateCE, RED
Other Specifications
WiringPress-in Type Terminals, wire diameter: 0.75-1.5mm²
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Dimension77.5×34.5×22mm
PackageBubble bag + Clapboard + Carton (K=A)
Net Weight58±2g
Lifetime5 years warranty @Ta 230V full load
Note: Detection area is affected by volume of motion object and motion speed. The detection area is tested by a 170cm height person walking at 0.3m/s.
Function Description
ON/OFF Function
The sensor is designed to connect one load only. Connecting more than one load may damage the sensor.
Ultra Slim Tri-proof Light ON/OFF Motion Sensor, Comply To Latest ERP Standard, Dip Switch Setting 0
Radiation Pattern
Ceiling Mounting
Ceiling mounted height: 3m
Sensitivity: 100%/75%/50%/25%
Ultra Slim Tri-proof Light ON/OFF Motion Sensor, Comply To Latest ERP Standard, Dip Switch Setting 1
Normal moving (Speed: 1m/s)
Ultra Slim Tri-proof Light ON/OFF Motion Sensor, Comply To Latest ERP Standard, Dip Switch Setting 2
Slow moving (Speed: 0.3m/s)
Ceiling mounted height: 6m
Sensitivity: 100%/75%
Ultra Slim Tri-proof Light ON/OFF Motion Sensor, Comply To Latest ERP Standard, Dip Switch Setting 3
Normal moving (Speed: 1m/s)
Ultra Slim Tri-proof Light ON/OFF Motion Sensor, Comply To Latest ERP Standard, Dip Switch Setting 4
Slow moving (Speed: 0.3m/s)
Only 100%/75% detection sensitivity is workable when installed at 6m mounting height. 25%/50% sensitivity is not able to detect motion signal.
DIP Switch Settings
Daylight Sensor Settings
Switch 1Switch 2Switch 3Setting
ONONON2Lux
-ONON10Lux
-ON-30Lux
--ON50Lux
---Disable
Hold Time Settings
Switch 4Switch 5Switch 6Setting
ONONON5S
ONON-30S
ON-ON90S
ON--5min
-ONON20min
---30min
Detection Area Settings
Switch 7Switch 8Setting
ONON100%
ON-75%
-ON50%
--25%
"Disable" means the daylight sensor does not work. It will turn on light once motion is detected regardless of ambient light.
Override Function

Power off, then quickly switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2 seconds to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.

Initialization

After power on, the sensor automatically turns on light at 100% brightness. After 10 seconds, it turns off the light. During initialization, the sensor is not able to detect movement.

Factory Settings

Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable

Application Notice
  • The sensor should be installed by a professional electrician. Please turn off power before installing, wiring, or changing DIP switch settings.
  • Sensors installed in plastic and glass lampshades will reduce sensitivity. For every 3mm increase in thickness, sensitivity reduces by 20%.
  • Light sensitivity threshold is measured in sunny environments without shadows or ambient light diffuse reflection. Ambient lux levels vary by environment, weather, climate, time-of-day, and season.
  • Sensor parameters may need reconfiguration in different installation environments.
  • This sensor is for indoor use only. Outdoor use affects waterproofing. Wind, rain, and moving objects may cause false triggering.
  • Distance between any inductive sensors should be greater than 3m.
  • Do not place sensor close to high-density objects like metal, glass, or concrete walls to avoid false triggering. When installed in metal lamps, reflective surfaces, or enclosed environments, microwave reflection may cause false triggering - reduce sensitivity or contact manufacturer for support.
  • Ensure no moving signals around sensor (fans, DC motors, sewer pipes, air outlets) to prevent false triggers.
  • Test 5 samples before mass application in new lighting projects.
  • Product specifications subject to change without notice due to continuous improvement.
  • When sensor is built under metal board, ensure sensor surface is seamlessly close to metal plate without space.